Firefighter Shut-Off Specs
|
 |
|
|
 |
The
Little Firefighter Automatic Shut-Off Valve
is the most lightweight and compact valve sold
on the market. Automatically shuts off gas
when triggered by a significant seismic event.
Easy 1/8 turn of coin slot for emergency manual
shut-off. Complies with all codes. It comes
with a 30 year warranty on all parts.
Order
This Valve! | Warranty |
Seismic
Gas Shut-Off Valve Operation
AGV-Series Valve
Operation (Horizontal)

VAGV-Series Valve Operation
(Vertical)

Please take a moment to understand the simplicity
of our valves operation. It has been our experience
the the simpler the operation the more consist
ant and accurate the function when needed. Each
valve is tested and certified before leaving
our factory insuring it meets UL and Los Angeles
Counties strict approvals.
- Both Valve Styles
Shut-Off Gas Flow When Triggered by a 5.4 Magnitude
Earthquake at the Valves Location.
- All Designs
are Patented or Patent Pending
- Valves Have Been
Tested to ASCE 25-97, State of California 12-23-1 & ANSI
Z21.70-1981 Standards for Seismic Gas Valves
" Designed
to shut-off gas flow to your home
in an earthquake and reduce destructive
fires."
- Complies With All State, City, & Laboratory
Testing Requirements
- Most Compact State-of-the-Art Design
- 30 Year Warranty On All Parts
- Automatically Shuts-Off Gas in
a 5.4 Magnitude Seismic Event
- Emergency Manual Shut-Off
Dependable
and safe your family is protected from
earth quake related gas fires 24-7 whether
your home or not our AGV-75 & VAGV-75
gas valves bring you piece of mind. Our
gas valves meet or exceed the requirements
of the City of Los Angeles, along with
UL Laboratory certification. When safety
counts, depend on Fire Fighter Gas Safety
Products.
| 3/4" Gas
Shut-Off Valve Specifications |
|
Model#
|
Pipe
Size
|
Max.
Pressure |
Length |
Width
|
Height |
Weight
|
|
1.0"W.C
BTU/HR
x1000
|
Effective
Pipe
Length
|
Cv
Value
|
| AGV-75 Horizontal |
3/4" npt
|
5
psi |
3" |
1-1/2"
|
3" |
1
lbs.
|
692 |
977
|
3.4'
|
18.1
|
| VAGV-75 Vertical |
3/4" npt
|
10
psi |
2-1/2" |
2"
|
3-3/8" |
1
lbs.
|
600 |
895
|
3.0
|
16.4
|
The
AGV-100, HAGV-100 & HAGV-100-HP series
valves are use in large homes and some
small industrial applications. At your
home or office our valves work 24-7 to
protect lives and property from earth quake
related gas fires. Please remember our
gas valves meet or exceed the requirements
of the City of Los Angeles, and are UL
Laboratory tested and certified. When safety
counts, depend on Fire Fighter Gas Safety
Products.
| 1" Gas
Shut-Off Valve Specifications |
|
Model#
|
Pipe
Size
|
Max.
Pressure |
Length |
Width
|
Height |
Weight
|
|
1.0"W.C
BTU/HR
x1000
|
Effective
Pipe
Length
|
Cv
Value
|
|
AGV-
100 Horizontal
|
1" NPT
|
5
psi |
4" |
1-3/4"
|
3-1/2" |
1.5
Lbs.
|
1,153 |
1,628
|
4.5'
|
30.2
|
|
VAGV-
100 Vertical
|
1" NPT
|
10
psi |
2-1/2" |
2"
|
3-3/8" |
1
Lbs.
|
515 |
765
|
10.0'
|
14.1
|
The
AGV-125, HAGV-125 & HAGV-125-HP series
valves are use in large homes and some
small industrial applications. At your
home or office our valves work 24-7 to
protect lives and property from earth quake
related gas fires. Please remember our
gas valves meet or exceed the requirements
of the City of Los Angeles, and are UL
Laboratory tested and certified. When safety
counts, depend on Fire Fighter Gas Safety
Products.
| 1-1/4" Gas
Shut-Off Valve Specifications |
|
Model#
|
Pipe
Size
|
Max.
Pres. |
Length |
Width
|
Height |
Weight
|
|
1.0"W.C
BTU/HR
x1000
|
Effective
Pipe
Length
|
Cv
Value
|
|
AGV-125 Horizontal
|
1-1/4"npt
|
5
psi |
4" |
2-1/3"
|
4-2/3" |
3
lbs.
|
1,889 |
2,677
|
6.9'
|
49.6
|
|
VAGV-125 Vertical
|
1-1/4"npt |
10
psi |
2.5" |
2" |
3.4" |
1
lbs. |
440 |
650 |
75.0' |
12.0 |
|
VAGV-125-HF Vertical
|
1-1/4"npt |
2
psi |
4.2" |
3.3" |
5.2" |
7
lbs. |
2,400 |
3,700 |
4.0' |
56.5 |
The
AGV-150, AGV-150-HP, HAGV-150& HAGV-150-HP
series valves are use in commercial applications.
At your office our valves work 24-7 to
protect lives and property from earth quake
related gas fires. Please remember our
gas valves meet or exceed the requirements
of the City of Los Angeles, and are UL
Laboratory tested and certified. When safety
counts, depend on Fire Fighter Gas Safety
Products.
| 1-1/2" Gas
Shut-Off Valve Specifications |
|
Model#
|
Pipe
Size
|
Max.
Pressure |
Length |
Width
|
Height |
Weight
|
|
1.0"W.C
BTU/HR
x1000
|
Effective
Pipe
Length
|
Cv
Value
|
|
AGV-
150 Horizontal
|
1-1/2"npt
|
5
psi |
6" |
3"
|
5-1/2" |
6
lbs.
|
4,079 |
5,759
|
10.0"
|
107.0
|
|
VAGV-
150 Vertical
|
1-1/2"npt |
2
psi |
4.2" |
3.3"" |
5.2" |
7
lbs. |
2,400 |
3,700 |
6.0' |
68.8 |
|
AGV-150-HP Horizontal
|
1-1/2"npt |
60
psi |
6" |
3" |
5-1/2" |
6
lbs. |
4.079 |
5,759 |
10.0' |
107.0 |
|
VAGV-150-HP Vertical
|
1-1/2"npt
|
60
psi |
4.2" |
3.3"
|
5.2" |
7
lbs.
|
2,400 |
3,700
|
6.0'
|
68.8
|
The
AGV-200, AGV-200-HP, HAGV-200 & HAGV-200-HP
series valves are use in commercial and
large business applications. At your office
our valves work 24-7 to protect lives and
property from earth quake related gas fires.
Please remember our gas valves meet or
exceed the requirements of the City of
Los Angeles, and are UL Laboratory tested
and certified. When safety counts, depend
on Fire Fighter Gas Safety Products.
| 2" Gas
Shut-Off Valve Specifications |
|
Model#
|
Pipe
Size
|
Max.
Pressure |
Length |
Width
|
Height |
Weight
|
|
1.0"W.C
BTU/HR
x1000
|
Effective
Pipe
Length
|
Cv
Value
|
|
AGV-200 Horizontal
|
2" npt
|
5
psi |
6" |
3"
|
5-1/2" |
6
lbs.
|
4,079 |
5,759
|
10.0'
|
107.0
|
|
VAGV-200 Vertical
|
2" npt |
2
psi |
4.2" |
3.3" |
5.2" |
7
lbs. |
1,800 |
2,500 |
40.0' |
46.8 |
|
AGV-200-HP Horizontal
|
2" npt |
60
psi |
6" |
3"
|
5-1/2" |
6
lbs.
|
4,079 |
5,759
|
10.0'
|
107.0
|
|
VAGV-200-HP Vertical
|
2" npt
|
60
psi |
4.2" |
3.3"
|
5.2" |
7
lbs.
|
1,800 |
2,500
|
40.0'
|
46.8
|
|
|
|
|